Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
Permit Number - T06PL02028
Inspection Description - PLUMBING - GAS PRESSURE TEST
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/16/2006 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* OK TO CONNECT GAS CLAMP TUBING IN ATTIC |
|
11/14/2006 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1/2" PIPING IS NOT LARGE ENOUGH FOR WH AND STOVE. CONNECT STOVE PIPING TO 1 1/4" MAIN. AT GRILL 3/4" IS REQUIRED TO POINT OF CONNECTION. USE SCOTCHKOTE AND DO A NEATER JOB OF WRAPPING. |