Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/21/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 15 PSI TEST OK GAS CARD AT METER 889-1888 |
|
| 11/07/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* TEST SHALL HOLE WITH NO PRESSURE LOSS. 1. REMOVE TEE CONNECTION AT METER LOCATION FOR FUTURE GAS PIPING. 2. VENT FROM WATER HEATER IS NOT CONNECTED AT CEILING SHALL BE CORRECTLY INSTALLED WITH 3-GALV SCREWS AT EACH JOINT OF FLUE VENT PIPING FOR WATER HEATER & FURNACE. 3. VENTS FROM WATER HEATER/FURNACE SHALL TERMINATE MINIMUM 2' ABOVE COMBUSTION AIR INTAKE & COOLER INTAKE WHEN WITHIN 10' OF INTAKES WITH DOUBLE WALL VENT PIPES & CAPS. |