Permit: T06PL02000

Parcel: 136280230


Addresses:

4311 S BOXWOOD PL

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/08/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
1) 12 PSI TEST UNDERGROUND FROM METER UP OVERHEAD TO WATER HEATER/FURANCE OK
2) GAS CARD AT METER
11/07/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- DO NOT USE THREADED PROTECTORS AS COUPLINGS.
REPLACE AS NEEDED. RETEST SYSTEM.
- EXTEND GAS DOWN TO WATER HEATER & FURNACE
- PROVIDE A ROOF JACK AT ROOF PENTRATION CLAMP GAS PIPE ON ROOF.
- PROVIDE SEDIMENT TRAPS AT APPLIANCES.