Permit: T06PL01994

Parcel: 111072740

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/05/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
12/01/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
13 PSI
PIPING SUPPORTS ON HORIZONTAL PIPE SHALL NOT EXCEED 8'
COMPLETE VENTING OF WH
SECURE VENT W/GALV SHEET METAL SCREWS
T&P SHALL BE APPROVED MATERIAL FOR HOT WATER.
TERMINATE WITHOUT THREADS.
11/28/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
COMPLETE PIPING AT APPLIANCES, INSTALL SEDIMENT TRAPS AT WH AND FURN. INSTALL WATER HEATER, WH VENT AND TEMP/PRESS RELIEF DRAIN TO EXTERIOR.
1" REQUIRED TO FIRST BRANCH USE FULL SIZE TEE.
11/21/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
- SUPPORT PIPING W/LISTED PIPE CLAMPS
NOT METAL STRAPPING
- PROVIDE ACCESS TO ALL GAS APPLIANCES AND PIPING.