Permit: T06PL01939

Parcel: 128020530


Addresses:

6221 E 16TH ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/04/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
PETITION OF APPEAL #207
ON SITE
11/03/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE NIPPLE WITH NO THREADS ON DISCHARGE END OF 125# PRESSURE RELIEF.
2. BREAK OFF TAMPER SCREW ON NEW HOSE BIB.
3. PROVIDE 125# PRESSURE RELIEF AT EXTERIOR NOT 150#
4. VENTS FROM WATER HEATER & FURNACE TO HAVE 3-GALV SCREWS AT EACH JOINT BE MADE UP CORRECTLY AND TERMINATE 2' MINIMUM ABOVE COMBUSTION AIR INTAKE OR COOLER INTAKE WHEN WITHIN 10' OF INTAKE WITH DOUBLE WALL VENT PIPE & APPROVED VENT CAP.
5. PLUG DRAIN PAN DRAIN
6. PROVIDE UPPER COMBUSTION AIR OF 100 SQ. INCHES FOR WATER HEATER.

CALL IN ALL INSPECTIONS T06PL01939, T06PL01945, T06PL01917 AS REQUESTED ON INSPECTION SHEETS ALL HAVE NOTES TO BE COMPLIED WITH. PLEASE READ AND COMPLY WITH ALL NOTES ON ALL SHEETS.
11/02/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
10:34 NO ACCESS