Permit: T06PL01902

Parcel: 134260700


Addresses:

6719 E MONTECITO DR

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
10/31/2006 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
15 PSI TEST OVERHEAD TO WATER HEATER/FURNACE APPROVED
GAS CARD AT METER 889-1888
10/30/2006 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
CONTRACTOR CANCELLED
10/27/2006 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
10/26/2006 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
CONTRACTOR CANCELLED
10/25/2006 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. TEST SHALL HOLD WITH NO PRESSURE LOSS
2. BONDING TO COLD WATER PIPING
3. PROVIDE VACUUM BREAKER AT HOSE BIB
4. PROVIDE FLEX AT FURNACE RATED FOR BTU'S