Permit: T06PL01901

Parcel: 136120670


Addresses:

9637 E MYRA DR

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
10/31/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
15 PSI TEST UNDERGROUND TO EXISTING SERVICE ENTRY TO WATER HEATER/FURNACE OK

GAS CARD AT METER S.W GAS 889-1888
10/30/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PROVIDE OR HAVE NEW WATR HEATER ADDED TO PERMIT.
2. REMOVE FUTURE TEE AT EXTERIOR OR PROVIDE CITY APPROVED GAS ISOMETRIC PLAN & RETEST SYSTEM.
10/27/2006 PLUMBING - FINAL Cancelled IVRS - RI canceled
10/27/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- T&P DRAIN APPEARS TO BE PLUGGED, OR IS NOT OPERATIONAL.
- THREAD PROTECTOR AT FURN IS NOT AN APPROVED COUPLING.
- SOME SHEETMETAL SCREWS AT B VENT DID NOT PENETRATE VENT CONNECTOR.
- REMOVE FUTURE GAS PIPE OR PROVIDE A PLAN, INCLUDE LOCATION OF GRILL ON PLAN.
10/25/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. REMOVE TAPE AT SINGLE TO DOUBLE WALL VENT CONNECTION ON WATER HEATER/FURNACE PROVIDE 3-GALV SCREWS AT ALL VENT CONNECTIONS.
2. WATER HEATER T&P TO GRAVITY DRAIN TO DAYLIGHT.
3. PROVIDE SEDIMENT TRAPS AT WATER HEATER/FURNACE GAS ENTRY.
4. PROVIDE APPROVED GAS VALVES FOR ALL APPLIANCES.
5. IF A FUTURE GAS CONNECTION IS DESIRED PROVIDE CITY APPROVED GAS ISOMETRIC.
6. PROVIDE APPROVED COUPLING AT FURNACE GAS ENTRY.
7. SEAL GAS ENTRY INTO BUILDING.