Permit: T06PL01881

Parcel: 136415240

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
10/30/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
10/26/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
COMPLETE ALL ITEMS LISTED AS REQUESTED
PAY REFEE
THEN CALL FOR REINSPECTION
10/24/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. SECURE ANGLE STOPS CORRECTLY AT ALL LOCATIONS.
2. PROVIDE SEPARATION OF HOT & COLD TUBING
3. SECURE TUBING AT CORRECT INTERVALS IN ATTIC SPACE PER MANUFACTURER
4. WATER HEATER SUPPLY IN ATTIC TO NOT BE IN CONTACT WITH METAL STRAPPING.
5. WATER HEATER TO HAVE MINIMUM 18" COPPER IN WALL
6. HAVE NEW WATER HEATER ADDED TO PERMIT
7. PROVIDE WATER FLEXES TO WATER HEATER THAT ARE NOT KINKED TO HOT SINK.
8. DO NOT BLOCK ATTIC ACCESS WITH TUBING