Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T06PL01879

Parcel: 113093210


Addresses:

2481 N FREMONT AV

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
11/02/2006 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
CORRECTIONS MADE OK
UCC LEFT AT METER
OK FOR GAS
SW GAS 889-1888
10/26/2006 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
1. UNABLE TO DO INSPECTION NO ONE HOME 1:25 PM
2. CALL 400-7004 BEFORE - NO ANSWER
10/23/2006 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
1. SEAL EXTERIOR WALL PENETRATIONS
2. PROVIDE BOND BETWEEN GAS PIPE AND WATER PIPE
3. PROVIDE SEDIMENT TRAPS AT FURNACE AND WATER HEATER (WATER HEATER GAS VALVE TO BE ACCESSIBLE)
4. PROVIDE INSPECTION HISTORY FOR NEW ROOFTOP GAS PACK.