Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
Permit Number - T06PL01844
Inspection Description - PLUMBING - GAS PRESSURE TEST
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/05/2006 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* T&P SHALL GRAVITY DRAIN TO EXTERIOR W/OUT TRAPS AND SHALL BE OF MATERIAL MADE FOR WATER PIPING. SECURE PIPING AT WH/FURN LOCATION OK FOR GAS AFTER CORRECTING -- RECALL FOR FINAL APPROVAL. |
|
11/14/2006 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* SEE NOTES FROM PREVIOUS INSP. PIPING IS UNDERSIZED EXISTING PIPING WAS 1" 1" PIPING NECESSARY FOR 135,000 BTU AT 80' PRESSURE TEST ENTIRE SYSTEM AGA VALVES REQUIRED, SEDIMENT TRAPS REQUIRED FLEX NOT ALLOWED ON T&P LOCATE & EXPOSE T&P TERMINATION REMOVE TAPE AT VENT CONNECTION, SECURE W/SCREWS PIPE SUPPORTS & CLAMPS REQUIRED ON ROOF AT 6' INTERVALS. ELECTRICAL BONDING REQUIRED. |
|
10/27/2006 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* - ROUTE GAS PIPE RISER AT METER -- TO METER IN A MANOR THAT DOES NOT BLOCK GATE. - HORIZONTAL PIPING SHALL BE 6" ABOVE DIRT - GAS PIPE PRIMER REQUIRED ON ALL TOOL MARKS AND FITTINGS PRIOR TO TAPE. - FLASHINGS REQUIRED AT ROOF PENETRATIONS - CHECK PIPE SIZING - PROVIDE ACCESS TO ALL GAS APPLIANCES AND PIPING. - NO ONE HOME 30 MIN. CALL GIVEN WAITED FOR 10 MIN. AFTER ARRIVING. |
|
10/23/2006 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* |