Permit: T06PL01844

Parcel: 133323670


Addresses:

540 N GOLLOB RD


Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Permit Number - T06PL01844

Inspection Description - PLUMBING - GAS PRESSURE TEST

Inspection Status - Approved

Date Description Inspector Results Comments
12/05/2006 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
T&P SHALL GRAVITY DRAIN TO EXTERIOR W/OUT TRAPS AND SHALL BE OF MATERIAL MADE FOR WATER PIPING.
SECURE PIPING AT WH/FURN LOCATION
OK FOR GAS AFTER CORRECTING --
RECALL FOR FINAL APPROVAL.
11/14/2006 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
SEE NOTES FROM PREVIOUS INSP. PIPING IS UNDERSIZED
EXISTING PIPING WAS 1"
1" PIPING NECESSARY FOR 135,000 BTU AT 80'
PRESSURE TEST ENTIRE SYSTEM
AGA VALVES REQUIRED, SEDIMENT TRAPS REQUIRED
FLEX NOT ALLOWED ON T&P
LOCATE & EXPOSE T&P TERMINATION
REMOVE TAPE AT VENT CONNECTION, SECURE W/SCREWS
PIPE SUPPORTS & CLAMPS REQUIRED ON ROOF AT 6' INTERVALS.
ELECTRICAL BONDING REQUIRED.
10/27/2006 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
- ROUTE GAS PIPE RISER AT METER -- TO METER IN A MANOR THAT DOES NOT BLOCK GATE.
- HORIZONTAL PIPING SHALL BE 6" ABOVE DIRT
- GAS PIPE PRIMER REQUIRED ON ALL TOOL MARKS AND FITTINGS PRIOR TO TAPE.
- FLASHINGS REQUIRED AT ROOF PENETRATIONS
- CHECK PIPE SIZING
- PROVIDE ACCESS TO ALL GAS APPLIANCES AND PIPING.
- NO ONE HOME 30 MIN. CALL GIVEN
WAITED FOR 10 MIN. AFTER ARRIVING.
10/23/2006 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*