Date Description Inspector Results Comments
11/08/2006 PLUMBING - GAS PRESSURE TEST Approved
11/06/2006 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
NO ONE HOME
UNABLE TO DO INSPECTION - 8:40 AM
11/02/2006 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
1. FLUE VENT FOR WATER HEATER PROVIDE DOUBLE WALL VENT THROUGH ROOF.
2. UNABLE TO INSPECT INSIDE HOUSE.
3. HAVE KEY TO HOUSE FOR INSPECTION.
4. LIST MAY NOT BE COMPLETE.
10/18/2006 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. GAS PRESSURE TEST FAILED (DROPPED .5 LBS IN 10 MIN.)
2. YOU SHOULD NOT HAVE BLACK IRON PIPE ON FLOOR OF UTILITY ROOM.
10/13/2006 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
PROVIDE PRESSURE TEST ON ALL GAS PIPING.