Permit: T06PL01817

Parcel: 136303250

Inspection Status: Denied

Inspection History: PLUMBING - FINAL

Permit Number - T06PL01817

Inspection Description - PLUMBING - FINAL

Inspection Status - Denied

Date Description Inspector Results Comments
10/23/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
READ #1 NOTES, PAY REFEE, MAKE CORRECTIONS THEN CALL FOR FINAL.
OK FOR INTERIOR
10/18/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
READ ALL NOTES & COMPLY
10/16/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. HAVE NEW WATER HEATER ADDED TO PERMIT.
PROVIDE 3-GALV SCREWS AT EACH JOINT OF VENT PIPING AND REMOVE TAPE AT SINGLE TO DOUBLE WALL VENT CONNECTION. CORRECT DRAFT HOOD INSTALLATION ON HEATER.
2. PROVIDE 18" MINIMUM COPPER AT WATER HEATER IN WALL PIPING.
3. PROVIDE SEPARATION OF HOT & COLD PEX PIPING.
4. PROVIDE VACUUM BREAKERS ON ALL HOSE BIBS.