Inspection Status: Denied
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/18/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* SYSTEM TEST PSI AT 2.5 PSI CHECK FOR LEAKS. RETEST. T&P TERMINATION IS 6"-24" ABOVE GRADE GROUNDING |
|
| 04/17/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* PROVIDE PRESSURE TEST INSTALL AGA GAS SHUT OFF VALVES TERMINATE T&P DRAIN VERTICALLY 6" ABV GROUND USE GALV SHEETMETAL SCREWS ON B VENT PROVIDE 1" OF CLEARANCE AT B VENT PENETRATION |
|
| 04/12/2007 | PLUMBING - FINAL | Cancelled | ||
| 04/06/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 01/08/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PROVIDE AN AIR TEST ON SYSTEM USING A GAUGE WITH 1/10TH PSI INCREMENTATIONS. 2. INSTALL AGA VALVES AT GAS APPLIANCES UPSTREAM OF FLEX . 3. TERMINATE T&P AT WH 4. SECURE WH VENT, SUPPORT/SECURE PIPING DROP AT WH 5. PROVIDE CLEARANCE FROM WOOD AT B VENT 6. INSTALL SEDIMENT TRAPS AT WH AND FURNACE. |