Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/12/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* REPAIR AT HOUSE RISER ONLY 10 PSI TEST ON EXISTING SYSTEM OK GAS CARD AT METER 889-1888 |
|
| 10/11/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* I'M SORRY, AN ADULT SHALL BE PRESENT TO PROVIDE ACCESS AT TIME OF INSPECTION. PLEASE CALL IN BY 3:30 PM FOR INSPECTION TOMORROW AND LEAVE A CONTACT PHONE # IF YOU NEED TO BE CONTACTED. |
|
| 10/09/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. GAS SYSTEM TO BE TESTED IN ITS ENTIRETY. 2. PROVIDE PIPE PRIMER THAN TEN MIL TAPE UNDERGROUND FITTINGS & PIPE TO 6" ABOVE FINISH GRADE. 3. PROVIDE TEMPERATURE & PRESSURE RELIEF GRAVITY DRAIN TO DAYLIGHT. 4. PROVIDE MINIMUM 100 SQ. INCHES UPPER & LOWER COMBUSTION AIR INTAKE FOR WATER HEATER. 5. PROVIEE AGA OR CSA APPROVED GAS SHUT OFF VALVES AT APPLIANCES. |