Permit: T06PL01760


Addresses:

3450 E 34TH ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/29/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
BE SURE YOUR TRACER WIRE IS ABOVE GRADE AT 2-WAY CLEANOUT.
10/19/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. SHALL PROVIDE TRAFFIC RATED COVERS FOR CLEANOUTS AT INLINE LOCATIONS (2)
2. SHALL MAKE REPAIR TO EXISTING BUILDING DRAIN STUB JUST UPSTREAM OF 2-WAY CLEANOUT (PIPE CRACKED) AND VERIFY NO LEAKAGE WITH TEST.
10/17/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
EXISTING BUILDING DRAIN STUB (CAST IRON) UPSTREAM OF 2-WAY CLEANOUT DAMAGED AND SHALL BE PERMITTED & INSPECTED & CORRECTED TO FINAL THIS PERMIT.
10/13/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
10/13/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
AFTER HRS. INSP. PER JASON CALL ROBERT @ 971-9188 OR
CLAY 248-2759
PAID W/CHECK #1010

YOU HAVE BACK PITCH AT TWO WAY CLEANOUT
AND DOWNSTREAM OF CLEANOUT.
ALSO, THERE ARE SOMOE FLAT SPOTS AND TWO OTHER AREAS W/BACKPITCH. SOME AREAS HAVE 1/2" PER FT. FALL
PROVIDE UNIFORM SLOPE THROUGHOUT.
REPAIR BROKEN CAST IRON BUILDING DRAIN AT 2 WAY CO
IF NECESSARY TO GO INTO BUILDING FOR REPAIR, A SEPARATE PERMIT IS REQUIRED.
PROPERTY LINE CO IS TO REMAIN PER DETAIL ON PLAN. OFFSET CO W/WYE PATTERN FITTINGS TO A LOCATION INSIDE PROPERTY LINE AND PERPENDICULAR TO HCS TIE IN POINT.
10/12/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. SHALL PROVIDE PROPERTY LINE CLEANOUT THAT IS NOT IN RIGHT OF WAY. TRACER TO BE TO GRADE AT THIS LOCATION.
2. REMOVE DEBRIS FROM UNDER PIPING & AROUND PIPING PROVIDE MINIMUM FALL & SHADE PIPING CORRECTLY.
3. PROVIDE CORRECT COUPLING FOR BUILDING DRAIN TO BUILDING SEWER CONNECTION & RETEST.