Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/06/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 09/29/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* -"USE OF INTERVENING STEEL PIPE NIPPLES AT ANY POINT IN A COPPER WATER PIPING SYSTEM IS AN UNACCEPTABLE PRACTICE. THE INSTALLATION OF BRASS FITTINGS DOES NOT PROVIDE DIELECTRIC PROTECTION." - UPC CODE ANSWERS AND ANALYSIS LAST REVIEW 2004 - GALV NIPPLES IN A COPPER WATER SYSTEM HAVE NEVER BEEN ACCEPTABLE. - WHEN NECESSARY THE AUTHORITY HAVING JURISDICTION MAY WAIVE THIS PROVISION. - IT IS NOT NECESSARY IN THIS CASE - PROVIDE A FULL SIZE 3/4" COPPER OR BRASS CONNECTION FOR PRESSURE RELIEF VALVE. COMPLETE THE INSTALLATION OF YOUR VAC BREAKER. |
|
| 09/28/2006 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* 2006.189 PIPING & TEST OK GAS CARD LEFT PLUMBER SHALL COMPLETE THE CORRECTIONS NOTES ON 9/26 AND RECALL FOR FINAL INSPECTION. |
|
| 09/26/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* |