Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/28/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 09/26/2006 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* TEST OK CORRECT ALIGNMENT OF VENT CONNECTORS CORRECT VENT AT FURNACE. |
|
| 09/25/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 09/22/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* AFTER HRS. INSP. FOR KEVIN W/BAKER BROS. 631-1936 PAID W/CHECK #2547 - WH SHALL REST ON CONCRETE OR OTHER APPROVED BASE. - T&P SHALL BE OF APPROVED MATERIALS AND SHALL TERMINATE 6" ABOVE GRADE. - TYPE B VENT REQUIRES 1" OF CLEARANCE FROM WOOD. - NO TAPE AT DOUBLE WALL VENT. - WH FLUE COLLAR IS SMASHED FLAT. - CORRECT SLOPE AT FURNACE VENT. - BOND TO CW PIPE. UNIT 204 TYPE B VENT REQUIRED THROUGH ROOF IF PIPING TO CLOTHES DRYER, ADD TO DRAWING AND PROVIDE TEST. |