Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
Permit Number - T06PL01683
Inspection Description - PLUMBING - GAS PRESSURE TEST
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/22/2006 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* | |
| 09/21/2006 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* - PROVIDE A 10 PSI PRESSURE TEST USING A 15 PSI GAUGE - SECURE PIPING AT 6' INTERVALS WITH PIPE CLAPS. - USE WEATHER RESISTANT SUPPORTS - PROVIDE SEDIMENT TRAPS AT WH AND FURNACE - PIPE T&P DRAIN TO EXTERIOR TERMINATE 6" ABOVE GROUND - INSTALL FLASHING AT ROOF PENETRATION. - PROVIDE 1" CLEARANCE BETWEEN WH VENT AND WOOD |