Permit: T06PL01680

Parcel: 136230460


Addresses:

3432 S MYRTIS PL


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T06PL01680

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
09/22/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
09/20/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. REMOVE TAPE AT DRAFT SPACE FROM SINGLE TO DOUBLE WALL VENT CONNECTION.
2. PROVIDE PETITION OF APPEAL FORM FOR ALTERNATE FORM OF TEMPERATURE & PRESSURE RELIFE SIGNED BY CITY ON SITE WITH CORRECT INSTALLATION.
3. T&P DRAIN TO BE 1" ABOVE RIM OF PAN.
4. VENT FROM WATER HEATER TO BE MINIMUM 2' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' WITH APPROVED DOUBLE WALL VENT PIPE.