Permit: T06PL01674

Parcel: 140061750


Addresses:

3720 E NEBRASKA SV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
10/06/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
09/29/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. EXPOSE ALL PIPING UNDERGROUND FOR VIEWING, SHALL HAVE PRIMER THEN TAPE AT ALL UNDERGROUND FITTINGS.
2. FIREPLACE LOG LIGHTER TO HAVE LOG LIGHTER VALVE WITHIN 4' OF HEARTH IN SAME ROOM AS FIREPLACE & BE TESTED INTO FIREPLACE HEARTH.
3. CAP OLD GAS PIPING THAT IS ABANDONED.
4. WATER HEATER REQUIRES SEDIMENT TRAP.
5. WATER HEATER REQUIRES TEMPERATURE & PRESSURE RELIEF DEVICE GRAVITY DRAIN TO DAYLIGHT OR PETITION OF APPEAL WITH CORRECT INSTALLATION SIGNED BY CITY.
6. VENT FROM WATER HEATER TO BE CORRECT WITH 3-GALV SCREWS AT EACH JOINT.
7. BONDING TO BE TO BUILDING GAS PIPING & COLD WATER PIPING.
8. FURNACE REQUIRES SEDIMENT TRAP AT GAS ENTRY.
9. GAS PIPING TO BE SUPPORTED CORRECTLY ON ROOF.