Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/21/2006 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* P OF A #2006.182 |
|
| 09/15/2006 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* - 15 PSI GAUGE REQUIRED FOR TEST - AGA VALVES REQUIRED - VALVE AT WH NEED TO BE ACCESSIBLE - INSTALL SEDIMENT TRAPS AT WH AND FURNACE - T&P DRAIN FROM WH SHALL GRAVITY DRAIN TO EXTERIOR OR PROVIDE A PETITION OF APPEAL FORM AND COMPLY W/REQUIREMENTS OF PETITION OF APPEAL; INSTALL DRAIN PAN ADN 125 PRV. - WATER HEATER VENT NEEDS TO BE REPLACED W/DOUBLE WALL TYPE B VENT AND TERMINATE 3' ABOVE COOLER. - PROVIDE ELECTRICAL BONDING OF GAS LINE; GROUND TO WATER PIPE. |