Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/19/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 09/18/2006 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* 5.9 PSI IS THERE A LEAK? PROVIDE A TEST PRESSURE THAT IS AT LEAST 1/2 OF GAUGE RANGE. CORRECTIONS INSIDE OK. VENT EXTENSIONS SHALL BE TYPE B DOUBLE WALL PIPING T&P IS DRIPPING |
|
| 09/15/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* - PROVIDE A PRESSURE GAUGE WITH 1/10 PSI INCREMENTATIONS. - PROVIDE ELECTRICAL BONDING OF GAS LINE - T&P DRAIN SHALL NOT BE TRAPPED, ENSURE THAT T&P IS OPERATIONAL. - SECURE VENT PIPE W/GALV SHEET METAL SCREWS AT EACH JOINT - EXTEND TYPE B VENT TO 3' ABOVE FORCED AIR INLET. - INSTALL SEDIMENT TRAPS AT FUR AND WH |