Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/11/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* GAS CARD AT METER SW GAS 889-1888 |
|
| 10/09/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. WATER HEATER TEMPERATURE & PRESSURE RELIEF SHALL GRAVITY DRAIN. 2. SUPPORT GAS PIPING AT 8' INTERVALS ALONG WALL. 3. TEST TO BE IN PLACE AT TIME OF INSPECTION 10 PSI MINIMUM WITH NO LOSS OF PRESSURE. |
|
| 10/03/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* - USE SCOTCH COATED PIPE FOR UNDERGROUND SECTIONS & PRIMER & TAPE JOINTS. RETEST SYSTEM. - T&P DRAIN CANNOT BE REDUCED. - PROVIDE 3 SCREWS IN EACH JOINT OF WATER HEATER VENT CONNECTORS & CENTER DRAFT DIVERTER. - 3/8" I.D GAS FLEX NOT ADEQUATE FOR 100,000 BTU FURNACE |