Permit: T06PL01637

Parcel: 133332300


Addresses:

711 N JASMINE PL


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T06PL01637

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
09/20/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
09/19/2006 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
WH OK
TUBING IN ATTIC HAS 20' SPANS WITH NO CLAMPS
TUBING IS SUSPENDED WITH LESS THAN ADEQUATE SUPPORT
SUPPORT AND SECURE TUBING AT NOT MORE THAN 32" INTERVALS. RE-ROUTE TUBING IF NECESSARY.
09/18/2006 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
- PEX SHALL BE SUPPORTED AND SECURED AT 32" INTERVALS.
- 18" OF METALLIC TUBING REQUIRED AT CONNECTIONS NEAR WH. 18" FROM SWEAT JOINTS THAT MAY NEED REPLACEMENT IN FUTURE; IE. FLEXES AND SHUT OFF VALVE
- HB VAC BREAKERS REQUIRED
- OK TO COVER WALLS