Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/20/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 09/19/2006 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* WH OK TUBING IN ATTIC HAS 20' SPANS WITH NO CLAMPS TUBING IS SUSPENDED WITH LESS THAN ADEQUATE SUPPORT SUPPORT AND SECURE TUBING AT NOT MORE THAN 32" INTERVALS. RE-ROUTE TUBING IF NECESSARY. |
|
| 09/18/2006 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* - PEX SHALL BE SUPPORTED AND SECURED AT 32" INTERVALS. - 18" OF METALLIC TUBING REQUIRED AT CONNECTIONS NEAR WH. 18" FROM SWEAT JOINTS THAT MAY NEED REPLACEMENT IN FUTURE; IE. FLEXES AND SHUT OFF VALVE - HB VAC BREAKERS REQUIRED - OK TO COVER WALLS |