Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T06PL01632

Parcel: 135111180


Addresses:

7566 E 35TH ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
09/21/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
15 PSI TEST FROM METER THRU OUT BUILDING UNDERGROUND UP AT PORCH OVERHEAD TO
WATER HEATER & FURNACE ONLY OK.
GAS CARD AT METER.
09/19/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. TEST SHALL HOLD WITH NO PRESSURE LOSS
2. PROVIDE CORRECT BONDING OF BUILDING GAS AT HOUSE
3. REMOVE TAPE FROM DOUBLE WALL VENT PIPING FOR WATER HEATER AND SECURE CONNECTION TO DRAFT HOOD WITH GALV SCREWS.
4. PROVIDE CORRECT FLASHING AT PENTRATION THRU VENT DOWN TO FURNACE & WATER HEATER.
5.. SECURE DROP FOR GAS LINE TO WATER HEATER/FURNACE
WITH 2-HOLE STRAP.
09/14/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- ELECTRICAL BONDING REQUIRED
- BELOW GRADE PIPING SHALL BE INSTALLED IN A MANNR THAT WILL PROVIDE 12' OF COVER ABOVE PIPE.
- TOOL MARKS AND FITTINGS SHALL HAVE PRIMER APPLIED AND THEN WRAPPED W/10 MIL. TAPE.
- SEDIMENT TRAPS REQUIRED AT FURNACE & WH
- WH VENT SHALL BE SECURED W/SCREWS AT EACH JOINT
- NO TAPE AT DOUBLE WALL
- T&P SHALL CONNECT DIRECTLY TO WH, AND SHALL BE OPERATIONAL AND SHALL GRAVITY DRAIN TO EXTERIOR.
- HARD PIPE NO FLEXES
- PROVIDE FULL SIZE TEE AT WH FURNACE, 1/2" AND 3/4" ARE UNDERSIZED AT THIS LOCATION.
- FLASHING REQUIRED AT ROOF PENETRATION
- PIPING SHALL NOT BE BENT OR STRAINED, USE SWING JOINT TO COMPENSATE FOR SLOPE OF ROOF.