Permit: T06PL01618

Parcel: 121010350


Addresses:

5983 E EDISON PL

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
09/12/2006 PLUMBING - GAS PRESSURE TEST Approved
09/08/2006 PLUMBING - GAS PRESSURE TEST Partial Approval IVRS - Inspection :*
- PRESSURE TEST ON NEW PIPING FROM METER TO HOUSE FURNACE AND WH ONLY IS OK TO COVER AND CONNECT.
- 2003 CODE REQUIRES SEDIMENT TRAPS TO BE INSTALLED AT FURNACE AND WH.
- PROVIDE ELECTRICAL BONDING OF GAS PIPE.
- OK TO CONNECT GAS AFTER INSTALLING
- GAS METER IS ON
- PLEASE CORRECT T&P TERMINATION ON WH #2 WHICH IS STILL ON AND CONNECTED TO SEPARATE PIPE.
- RECALL FOR INSPECTION WHEN COMPLETE.