Permit: T06PL01536

Parcel: 136361470


Addresses:

7733 E VANCOUVER PL

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
09/01/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
08/28/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PROVIDE BONDING OF BUILDING GAS PIPING.
2. REMOVE DUCT TAPE FROM WATER HEATER VENT &
PROVIDE 3-GALV SCREWS AT EACH JOINT OF WATER HEATER VENT & FURNACE VENT.
3. WATER HEATER TEMPERATURE & PRESSURE RELIEF DRAIN SHALL GRAVITY DRAIN TO DAYLIGHT AND TERMINATE
AT 90 DEG. DOWN ON EXTERIOR.
4. PROVIDE SEDIMENT TRAPS AT GAS ENTRY TO WATER HEATER & FURNACE.
5. CAP OLD GAS PIPING ON INTERIOR.