Permit: T06PL01531

Parcel: 110043880


Addresses:

4338 E RED OWL LN

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/29/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
08/25/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
CHANGES OF DIRECTION IN HARD DRAWN COPPER ARE TO BE MADE WITH FITTINGS, ANNEALING TUBE AND HAND BENDING IS NOT ALLOWED. THERE ARE SEVERAL PLACES WHERE TUBING HAS BEEN DAMAGED. ALSO, ALL COPPER JOINTS ARE TO BE REAMED TO THE FULL ID OF THE TUBE. PIPE INSTALLERS WERE UNABLE TO PROVIDE A DEBURRING TOOL.