Permit: T06PL01513

Parcel: 11301013B


Addresses:

1715 E ALLEN RD


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T06PL01513

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
09/14/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
1. CORRECTIONS MADE OK
2. OK TO COVER GAS AND WATER
3. WATER HEATER AND FURNACE EXISTING
4. OK FOR GAS. UCC LEFT AT METER (SW GAS 889-1888)
09/01/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. 12.11.1.2(A) COVER REQUIREMENTS - I WILL REQUIRE 18" BECAUSE IT IS IN A TRAFFIC AREA. SAME WITH PVC WATER PIPING.
2. 1211.1.6 PIPING UNDER BUILDINGS (PORCHES INCLUDED) EVERYTHING UNDER THE PORCH OVERHANG IS CONSIDERED "UNDER THE BUILDING".
08/29/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
15 PSI TEST NOT HOLDING
1. INCORRECT SLEEVING UNDER FRONT PORCH.
2. TAPE & PRIMER ALL TOOL MARKS & BURNT COATING ON GAS PIPE. TAPE & PRIMER EXISTING FITTING AT HOUSE CONNECTION. ALL TAPE MUST BE TIGHT.
3. PIPE NOT RAN IN A STRAIGHT LINE.
4. ADD YARD WATER LINE TO PERMIT. IMPROPER TRANSITION FROM PVC TO COPPER.
5. GAS PIPE TO BE ON A FIRM BED THE ENTIRE LENGTH.
6. NEED ACCESS TO ALL APPLIANCES.