Permit: T06PL01480

Parcel: 140250860

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
10/26/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
10/10/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. WATER HEATER TO BE INSTALLED ON APPROVED BASE.
2. ADD SUPPORT TO GAS PIPING AND FLOOR
3. PROVIDE PSI TEST ON ALL GAS PIPING
4. REPAIR LEAK AT WATER METER.
5. PROVIDE COMBUSTION AIR AT WATER
6. PROVIDE GLUE CAN FOR CPVC PIPING.
7. PROVIDE PLASTIC METER THREADS AT SUPPLY TO WATER PIPING IN WATER HEATER CLOSET.
09/27/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. INSTALL M.H FLEX CONNECTOR AND VALVE.
2. WATER HEATER TO BE INSTALLED ON APPROVED BASE INSTALL T&P RELIEF DRAIN
3. PVC IS NOT APPROVED FOR HOT WATER PIPING PVC NOT APPROVED IN EXPOSED EXTERIOR LOCATION.
4. SECURE PERMIT FOR WATER REPIPE.
08/31/2006 PLUMBING - FINAL Cancelled CANCELLED PER MESSAGE LEFT ON EXT. 1126 ON 8/31/06
08/31/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*