Permit: T06PL01438

Parcel: 12403207B


Addresses:

1628 E 6TH ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
04/16/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
11/27/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
SEE PERMIT #T06PL02044
08/29/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. TEST SHALL HOLD WITH NO PRESSURE LOSS.
2. PROVIDE REVISED CITY APPROVED PLAN OF YOUR COMPLETE GAS PIPING SYSTEM AS INSTALLED.
3. VENTS FROM WATER HEATER & FURNACE TO BE MADE UP CORRECTLY, HAVE 3-GALV SCREWS AT EACH JOINT AND TERMINATE IN APPROVED MANNER ON ROOF.
4. WATER HEATER TO HAVE TEMPERATURE & PRESSURE RELIEF DRAIN GRAVITY TO DAYLIGHT.
5. GAS APPLIANCES TO HAVE LISTING PLATES.
6. OLD GAS PIPING TO BE CAPPED AND OR REMOVED.
7. CSST TO BE INSTALLED PER LISTING & SECURED CORRECTLY.
8. PROVIDE SEDIMENT TRAPS FOR FURNACE & WATER HEATER.

NOT COMPLETE LIST