Permit: T06PL01428

Parcel: 128120530


Addresses:

5033 E 18TH ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
08/23/2006 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
08/10/2006 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
- YOU HAVE UNWRAPPED TOOL MARKS BELOW GRADE
- PRIMER AND WRAP ALL TOOL MARKS
- PRIMER IS TO BE APPLIED BEFORE THE 10 MIL. TAPE
- PROVIDE ELECTRICAL BONDING
- WATER HEATER SHALL REST ON A 3" CONCRETE PAD AND SHALL BE INSTALLED PRIOR TO GAS UTILITY CLEARANCE.
- PROVIDE (ADD) PERMIT FOR WATER HEATER REPLACEMENT,
- ALSO, IT APPEARS THAT THIS HEATER IS BEING RELOCATED,
ALL PIPING SHALL BE INSPECTED.
- ALSO, PROVIDE PERMIT OR PROOF INSPECTION FOR NEW GAS FURNACE.
- NOTE VALVE IS IN THE ON POSITION AT FURNACE.