Permit: T06PL01425

Parcel: 135043110


Addresses:

6810 E CALLE ILEO

Inspection Status: Denied

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
09/12/2006 PLUMBING - GAS PRESSURE TEST Denied PLEASE RESCHEDULE AN INSPECTION WHEN SOMEONE WILL BE HOME. COULD NOT CHECK MESSAGES TODAY. SYSTEM NOT WORKING. JIM 909-4712
09/12/2006 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
08/31/2006 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
11 PSI
- PROVIDE MIN. 3 SCREWS IN ALL JOINTS OF VENT CONNECTORS
- REMOVE OLD GAS VALVES & USE APPROVED GAS SHUT OFF VALVES.
- BOND THE GAS PIPE WITH THE ELEC. SYSTEM.
- DO NOT USE 4' OF COPPER FLEX ON T&P RELIEF DRAIN.
- T&P RELIEF MUST DRAIN TO DAYLIGHT WITH SLOPE OR PROVIDE ALTERNATE METHOD WITH A PETITION OF APPEAL.
- YOU CANNOT HAVE BURIED GAS PIPE UNDER A STRUCTURE WITHOUT PROPER SLEEVING.
- RETEST SYSTEM.
- EXTEND FURNACE & WATER HEATER VENTS 2' ABOVE EVAP. COOLER.