Inspection History Details
Inspection Status: Partial Approval
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/04/2006 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* | |
| 08/03/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* NO ACCESS AT 2:22 PLEASE HAVE AN ADULT PRESENT TO PROVIDE ACCESS AT REINSPECTION. |
|
| 08/02/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* PLEASE SCHEDULE AN INSPECTION WHEN AN ADULT WILL BE PRESENT. NEED ACCESS TO ALL GAS APPLIANCES INSIDE HOUSE. BE SURE TO USE PRIMER & APPROVED TAPE ON ALL UNDERGROUND FITTINGS & TOOL MARKS THE LONG SECTION OF PIPE STRAPPED TO THE WALL MUST BE STRAIGHT. DO NOT USE COPPER PLUMBERS TAPE TO SUPPORT PIPE. USE A 2 HOLE STEEL STRAP. BE SURE TO HAVE ALL GAS PIPING FILLED WITH AIR. |