Permit: T06PL01333

Parcel: 115022930


Addresses:

345 E LINDEN ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/11/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
25 PSI TEST IS OK -- LEFT GAS CARD
CORRECTIONS HAVE BEEN MADE
GAS LINE TO OLD FURNACE CAPPED OFF.
08/04/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
25 PSI TEST OK TO BACKFILL

PROVIDE A DRAIN ON T&P RELIEF VALVE ON WATER HEATER.
VENT PIPE ON WATER HEATER UPSIDE DOWN. PROVIDE MIN. 1" CLEARANCE FROM WOOD.
SECURE VENT PIPE.
NO UNIONS ALLOWED IN A CONCEALED. RETEST SYSTEM.
FURNACE NOT OP. BOND GAS LINE TO ELEC. SERVICE
OK TO BACKFILL TRENCH.