Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/15/2006 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* | |
| 08/11/2006 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* 1. T&P RELIEF DRAIN TO BE HAND PIPED 2. CONNECT NEW PIPING TO EXISTING AND TEST CONNECTION AS WELL AS ALL GAS PIPING. 3. ALL OTHER CORRECTIONS MADE OK |
|
| 08/02/2006 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* - NO ANSWER AT CHURCH 8:40 AM - PROVIDE DOUBLE WALL TYPE B VENT WHERE PENETRATING WALL AND EXPOSED TO OUTSIDE. - PROVIDE CLEARANCE FROM COMBUSTIBLES - T&P VALVE DRIPPING - SEAL WALL PENETRATION - CONNECT NEW PIPING TO EXISTING AND TEST CONNECTION AS WELL AS ALL GAS PIPING. - GAUGE ON EXISTING PIPING IS LOSING PRESSURE - PROVIDE ACCESS TO ALL GAS APPLIANCES - PROVIDE ELECTRICAL BONDING OF GAS PIPING |