Inspection History Details
Inspection Status: Partial Approval
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/02/2006 | PLUMBING - GAS PRESSURE TEST | Partial Approval | IVRS - Inspection :* PRESSURE TEST OK PROVIDE CLEARANCE BETWEEN WH VENT AND WOOD EVE INSTALL A PIPE SUPPORT ON GAS PIPING TO WH PIPE IS RESTING ON HOLE IN ENCLOSURE INSTALL SUPPORT AT STOVE DROP GAS CARD LEFT OK FOR GAS BUT RECALL FOR FINAL APPROVAL |
|
| 07/31/2006 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* NO ONE HOME NOTE: WH HAS BEEN RELOCATED AT SOME TIME PRIOR. 18 1/2 PSI ON 30 PSI GAUGE WH VENT IS REQUIRED TO BE TYPE B DOUBLE WALL OUTSIDE OF ENCLOSURE. ALSO, SECURE VENT CONNECTOR W/GALV SHEET METAL SCREWS. CORRECT DRIPPING T&P PROVIDE ELECTRICAL BONDING OF GAS LINE SUPPORT PIPING TO W.H INSTALL SEDIMENT TRAP AT W.H SEAL WALL PENETRATION AT? (STOVE) SOUTH WALL PROVIDE ACCESS TO FURNACE FOR INSPECTION. |