Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/25/2006 | PLUMBING - GAS PRESSURE TEST | Approved | ||
| 08/02/2006 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* PRESSURE TEST ON REAR (EAST) HOUSE IS OK. PIPE REPAIR IS OK ONCE YOUR METER IS LOCKED OUT, IT BECOMES NECESSARY TO BRING YOUR ENTIRE GAS SYSTEM UP TO CODE. YOU HAVE A FAIRLY NEW WATER HEATER WHICH HAS NOT BEEN INSTALLED PER CODE. WH SHALL REST ON A LEVEL CONCRETE BASE NOT LESS THAN 3 1/2" ABOVE DIRT. T&P SHALL TERMINATE 6" - 24" ABOVE GRADE. DOUBLE WALL B VENT REQUIRED OUTSIDE OF ENCLOSURE COPPER PIPING SHALL BE SUPPORTED AND SHALL NOT TOUCH METAL. PROVIDE SEDIMENT TRAPS AND AN UPPER COMBUSTION AIR OPENING. PROVIDE ELECTRICAL BONDING SUPPORT PIPING ON ROOF PROVIDE ROOF PENETRATION FLASHING |
|
| 07/25/2006 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* CAREFULLY RE-READ THE NOTE FROM 7/24/06 AND COMPLY CONTINUED "NOT READY" MAY RESULT IN A REINSPECTION FEE |
|
| 07/24/2006 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* YOU HAVE AN ADDRESSING PROBLEM PERMIT IS FOR UNIT ONE TEST IS ON UNIT TWO EXPOSE ALL FITTINGS THAT HAVE BEEN REPAIRED OR REPLACED -- CORRECT THE ADDRESS BEFORE YOU RECALL INSPECTION. |