Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/08/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* REPAIR AT RISERS ONLY 15 PSI TEST FROM METER TO WATER HEATER/FURNACE OK. GAS CARD AT METER 889-1888 |
|
| 07/31/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* THIS IS A PLUMBING GAS REPIPE 1. PROVIDE PIPE PRIMER & TEN MIL. TAPE AT RISER AT METER. 2. PROVIDE WORKING TEST GAUGE IN 1/10 POUND INCREMENTS 3. PROVIDE BONDING OF BUILDING GAS PIPING. 4. PROVIDE SEDIMENT TRAPS AT GAS ENTRY TO WATER HEATER & FURNACE. 5. VENT FROM WATER HEATER/FURNACE TO BE 2' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' OF COOLER INTAKE WITH DOUBLE WALL VENT PIPING & CAP |
|
| 07/18/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* NO ACCESS AT 2:36 |