Permit: T06PL01258

Parcel: 136160540


Addresses:

8500 E LOUISE DR

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/08/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
REPAIR AT RISERS ONLY 15 PSI TEST FROM METER TO WATER HEATER/FURNACE OK.
GAS CARD AT METER 889-1888
07/31/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
THIS IS A PLUMBING GAS REPIPE
1. PROVIDE PIPE PRIMER & TEN MIL. TAPE AT RISER AT METER.
2. PROVIDE WORKING TEST GAUGE IN 1/10 POUND INCREMENTS
3. PROVIDE BONDING OF BUILDING GAS PIPING.
4. PROVIDE SEDIMENT TRAPS AT GAS ENTRY TO WATER HEATER & FURNACE.
5. VENT FROM WATER HEATER/FURNACE TO BE 2' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' OF COOLER INTAKE WITH DOUBLE WALL VENT PIPING & CAP
07/18/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
NO ACCESS AT 2:36