Permit: T06PL01241

Parcel: 107121220


Addresses:

2914 N STONE AV #05

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/02/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
GAS LINE PRESSURE TEST 15 PSI
07/31/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
NO ACCESS AT 10:25 AM
SHALL HAVE AN ADULT PRESENT TO PROVIDE ACCESS AT REINSPECTION.
07/18/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. FLEX CONNECTOR MAY NOT PASS THRU WALL OR PARTITION WALL FURNACE IS ONE APPLIANCE WHERE VALVE AND FLEX MAY BE UNDER FIREBOX.
2. REQUIRE SEDIMENT TRAP AT WATER HEATER.
3. DID NOT SEE BONDING BETWEEN WATER PIPE AND GAS PIPE.