Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06PL01231

Parcel: 125121090


Addresses:

964 N JONES BL #02


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T06PL01231

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
07/24/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
15 PSI TEST TOW PIPING FROM METER ABOVE GRADE TO WATER HEATER & STOVE ONLY
FURNACE GAS SUPPLY IS REMOVED WITH NO TEE CONNECTION.
GAS CARD AT METER -- SW GAS 889-1888
07/12/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
15 PSI TEST FROM METER TO STOVE, WATER HEATER & WALL HEATER PARTIAL APPROVAL.
1. SHALL CAP OLD GAS PIPING NOT BEING USED AT ALL LOCATIONS.
2. BONDING WIRE SHALL BE CONNECTED TO BUILDING SIDE OF DIELECTRIC UNION ON WATER PIPING.
3. PROVIDE PROOF OF PROPER VENTING OF WALL FURNACE. THIS HEATER APPEARS TO HAVE BEEN ALTERED FROM ITS LISTING FOR VENTING THIS SHALL BE CORRECTLY INSTALLED.
PROVIDE PROOF OF PROPER FURNACE OPERATION.
07/10/2006 PLUMBING - FINAL Cancelled CANCELLED PER BRIAN OF PLUMB/PLUMBING #629-0504
07/10/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*