Permit: T06PL01132

Parcel: 136071740

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
07/12/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
07/10/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. DO BOTH UNITS FROM #1 NOTE OF 7/3/06 INSPECTION.
2. SEE PAGE #12 FOR INSTALLATION OF PRV SUPPLIED WITH WATER HEATER AND INSTALL CORRECTLY.
07/03/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. VENTS FROM WATER HEATER & FURNACE TO BE MINIMUM 2' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' OF COOLER INTAKE WITH DOUBLE WALL VENT PIPE & CAP. PROVIDE 3-GALV SCREWS AT EACH JOINT OF VENT PIPING.
2. PROVIDE PERMIT FOR WATER HEATER AND HAVE FULL SIZE VENT THRU ROOF WITH INSPECTINO TO RECEIVE GAS CARD.
3. WATER HEATER TO HAVE TEMPERATURE & PRESSURE RELIEF PER MANUFACTURERS INSTALLATION INSTRUCTION.
4. PROVIDE BONDING OF BUILDING GAS PIPING.
5. PROVIDE SEDIMENT TRAPS AT GAS INLET TO WATER HEATER & FURNACE.