Inspection History Details
Inspection Status: Not ready for Inspection
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/28/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* VENT FROM FURNACE IS DOUBLE WALL THRU ROOF AND SHALL BE INSTALLED IN DIRECTION OF FLOW ON PIPING MADE UP CORRECTLY. WHEN EXTENDING TO 2' ABOVE COOLER INTAKE WITH APPROVED VENT CAP. |
|
| 07/27/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* VENTS FROM WATER HEATER & FURNACE TO BE MADE UP CORRECTLY. VENT FROM FURNACE TO BE 2' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' OF COOLER INTAKE. SEE NOTE #1 FROM 7/3 INSPECTION AND NOTE #7 |
|
| 07/07/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* PLUS MAKE UP WATER HEATER VENT CONNECTION CORRECTLY AT SINGLE TO DOUBLE WALL. WENT OVER ITEMS WITH OWNER THIS INSPECTION. |
|
| 07/03/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE 3-GALV SCREWS AT EACH JOINT OF VENT PIPING FOR WATER HEATER & FURNACE. 2. REMOVE DUCT TAPE AT SINGLE TO DOUBLE WALL VENT CONNECTION OF WATER HEATER. 3. WATER HEATER TEMPERATURE & PRESSURE RELIEF DRAIN SHALL GRAVITY DRAIN TO DAYLIGHT (CANNOT GO UP HILL) IF NOT POSSIBLE PROVIDE CITY SIGNED PETITION OF APPEAL ON SITE WITH CORRECT INSTALLATION. 4. PROVIDE BONDING OF BUILDING GAS PIPING. 5. INFORMED OWNER OF POSSIBLE DANGER OF LOCATION OF GAS BBQ TO ROOF OVERHANG. SEE PLATE AT KNOBS TO TURN ON. 6. PROVIDE SEDIMENT TRAPS AT GAS INLETS TO WATER HEATER & FURNACE. 7. MAKE PIPE FLASHINGS ON ROOF WEATHER TIGHT AND PROVIDE ROOF MASTIC TO SECURE BLOCKING TO ROOF. 8. NOTE: BE SURE YOUR WATER HEATER TEMPERATURE & PRESSURE RELIEF VALVE IS FUNCTIONING PROPERLY. 9. PROVIDE RIGID NIPPLE THRU FURNACE APPLIANCE HOUSING. |