Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/23/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 08/14/2006 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* 1. EXCEPT FOR SINGLE PIECE MANUFACTURED RISERS, PLASTIC GAS PIPE SHALL HAVE AT LEAST 30" OF HORIZONTAL HARD PIPE BEFORE VERTICAL RISER. 2. GAS PIPE TO BE AT LEAST 3 1/2" ABOVE GRADE MAY NOT LAY ON CONCRETE 3. PROVIDE BOND |
|
| 07/11/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. OK TO COVER UNDERGROUND NEED TO SEE THE REST OF THE PIPING AND MAKE ALL CONNECTIONS. |
|
| 07/10/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 06/29/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) PLASTIC GAS PIPE SHALL HAVE 18" OF COVER AT ALL POINTS 2) RISERS SHALL RISE VERTICALLY 3) HOW IS THE CONNECTION TO BE MADE AT THE HOUSE 4) IT IS NOT ADVISABLE TO TEST AT THE UPPER LIMITS OF THE GAGE |