Permit: T06PL01072

Parcel: 133042350


Addresses:

9441 E CALLE EUNICE

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
07/05/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
06/29/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) WATER HEATER TEMPERATURE AND PRESSURE RELIEF SHALL GRAVITY DRAIN TO DAYLIGHT. TERMINATE AT 90 DEGREE DOWN WITH APPROVED RIDGID PIPING
2) PROVIDE AGA OR CSA APPROVED GAS VALVES AT APPLIANCES
3) PROVIDE BONDING OF BLDG GAS PIPING
4) PRIME AND TAPE ALL TOOL MARKS ON UNDERGROUND PIPING
5) PROVIDE FIRM BED FOR PIPING TO ? ON IN DITCH