Inspection History Details
Inspection Status: Partial Approval
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/26/2006 | PLUMBING - GAS PRESSURE TEST | Partial Approval | IVRS - Inspection :* 1) PETITION OF APPEAL HAS NO CASE # OF SIGNATURE 2) PROVIDE A COMPLETE PETITION OF APPEAL THEN RECALL INSPECTION FOR FINAL APPROVAL 3) GAS CARD LEFT |
|
| 06/24/2006 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* GAUGE READING 0 CHECK FOR LEAKS - PROVIDE TEST RELIEF VALVE SHALL TERMINATE WITHOUT THREADS YOU HAVE INSTALLED A NEW HB. HBS REQUIRE VACUUM BREAKERS. SECURE PIPING BEHIND STOVE INSTALL PIPING AT WH LOCATION THAT WILL FACILITATE THE REMOVAL OF WH. PROVIDE A FLUX CONNECTOR RATED FOR A MINIMUM OF 125,000 BTU AT FURNACE. PLUG DRAIN PAN. |