Inspection History Details
Inspection Status: Not ready for Inspection
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/10/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. CORRECTIONS MADE OK 2. OK FOR GAS 3. UCC LEFT AT METER SW GAS 889-1888 |
|
| 07/05/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) ROOF PEUTRATION REQUIRES A FLASHING 2) ROOF TOP GAS TO BE SUPPORTED IN AN APPROVED MANOR 3) WILL REQUIRE TONDING BETWEEN GAS AND WATER PIPING 4) OK TO COVER UNDER GROUND |
|
| 06/21/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE PIPING THAT IS APPROVED FOR BURIAL. PIPING SHALL BE FACTORY COATED OR P.E. WITH ALL FITTINGS & TOOL MARKS PRIMED THEN TAPED IF UNDERGROUND 2. NO PIPING SHALL BE UNDERGROUND UNDER BUILDING OR STRUCTURE. 3. RIPING TO BE FROM METER LOCATION TO ALL APPLIANCES. ALL APPLIANCES TO HAVE APPROVED AGA OR CSA GAS SHUT OFF VALVES. 4. PROVIDE BONDING OF BUILDING GAS PIPING. THIS IS NOT A COMPLETE LIST. 2. |