Permit: T06PL01004

Parcel: 134241180


Addresses:

6426 E DUKE DR


Inspection Status: Not ready for Inspection

Inspection History: PLUMBING - FINAL

Permit Number - T06PL01004

Inspection Description - PLUMBING - FINAL

Inspection Status - Not ready for Inspection

Date Description Inspector Results Comments
06/21/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
VENT FROM FURNACE TO BE PERMANENTLY SECURED IN VERTICAL POSITION.
06/21/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
06/19/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. WATER HEATER T&P DRAIN SHALL TERMINATE 6"-24" FROM FINISH GRADE AT DOWNWARD ANGLE.
2. VENT FROM FURNACE EXHAUST SHALL BE 2' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' OF COOLER INTAKE.
3. WATER HEATER DRAFT HOOD TO BE INSTALLED IN CORRECT POSITION.