Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/03/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* PETITION OF APPEAL #2006.126 ON SITE NOTE: THERE IS A DIFFERENCE BETWEEN DRIP LEG & SEDIMENT TRAP. IN FUTURE PROVIDE SEDIMENT TRAP AS REQUESTED. GAS CARD AT METER. |
|
| 06/28/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PRESSURE TEST OK ( IN FUTURE USE A GAGE WITH 1/10 PSI INCREMENTATION) 2) T & P DRAIN FROM WATER HEATER SHALL GRAVITY DRAIN TO EXTERIOR OR PROVIDE A PETITION OF APPEAL FORM WHICH CAN BE OBTAINED AT 201 N. STONE. PROVIDE AN OPERATING T & P VALVE. THIS WILL BE TESTED AT NEXT INSPECTION 2) SECURE VENT CONNECTOR WITH GALV SHEET METAL SCEWS 3) SECURE PIPE DRO AT WH 4) INSTALL A SEDIMENT TRAP AT WATER HEATER |