Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/21/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* CORRECTIONS HAVE BEEN MADE 9 PSI TEST OK LEFT GAS CARD |
|
| 06/15/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* OBTAIN PERMIT FOR NEW FURNACE AND WATER HEATER. HAVE FURNACE INSPECTED PRIOR TO GAS PIPING INSPECTION. NEW FURNACE NOT PROPERLY INSTALLED. NEW WATER HEATER DATED 2002. NOT PROPERLY INSTALLED. SUPPORT PIPING AT WH AND AT FURNACE. PROVIDE NEW APPLIANCE CONNECTOR AT WH AND FURNACE. PROVIDE WH DRAIN PAN TO PROTECT WOOD PLATFORM. PROVIDE T&P GRAVITY DRAIN TO EXTERIOR. PROVIDE CORRECT VENT CONNECTOR AT WATER HEATER. PROVIDE FULL PORT WATER SHUT OFF ON NEW WH. CAST PIPING EXPOSED REQUIRES SLEEVING. ROOF PENETRATION REQUIRES FLASHING. |
|
| 06/14/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. I GAVE THIRTY MINUTES NOTICE 2. NO ANSWER AT DOOR |